| Annals of Surgical Innovation and Research | |
| Use of a radiopaque localizer grid to reduce radiation exposure | |
| Kee D Kim2  Wentao Li3  Caren L Galloway1  | |
| [1] Department of Neurological Surgery, University of California, Davis, 4860 Y Street Suite 3740, Sacramento, CA 95816, USA | |
| [2] Department Neurological Surgery, University of California, Davis, 4860 Y Street Suite 3740, Sacramento, CA 95816, USA | |
| [3] Department of Molecular and Cell Biology, University of California, Berkeley, 142 LSA #3200, Berkeley, CA 94720, USA | |
| 关键词: Grid; Innovation; Localization; Spine Surgery; Minimally Invasive; Exposure; Radiation; | |
| Others : 793186 DOI : 10.1186/1750-1164-5-6 |
|
| received in 2011-05-27, accepted in 2011-08-09, 发布年份 2011 | |
PDF
|
|
【 摘 要 】
Background
Minimally invasive spine surgery requires placement of the skin incision at an ideal location in the patient's back by the surgeon. However, numerous fluoroscopic x-ray images are sometimes required to find the site of entry, thereby exposing patients and Operating Room personnel to additional radiation. To minimize this exposure, a radiopaque localizer grid was devised to increase planning efficiency and reduce radiation exposure.
Results
The radiopaque localizer grid was utilized to plan the point of entry for minimally invasive spine surgery. Use of the grid allowed the surgeon to accurately pinpoint the ideal entry point for the procedure with just one or two fluoroscopic X-ray images.
Conclusions
The reusable localizer grid is a simple and practical device that may be utilized to more efficiently plan an entry site on the skin, thus reducing radiation exposure. This device or a modified version may be utilized for any procedure involving the spine.
【 授权许可】
2011 Kim et al; licensee BioMed Central Ltd.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 20140706194723607.pdf | 459KB | ||
| Figure 6. | 120KB | Image | |
| Figure 5. | 61KB | Image | |
| Figure 4. | 49KB | Image | |
| Figure 3. | 42KB | Image | |
| Figure 2. | 11KB | Image | |
| Figure 1. | 39KB | Image |
【 图 表 】
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
Figure 6.
【 参考文献 】
- [1]Cleary K, Clifford M, Stoianovici D, Freedman M, Mun SK, Watson V: Technology improvements for image-guided and minimally invasive spine procedures. IEEE Trans Inf Technol Biomed 2002, 6(4):249-61.
- [2]Barrett C, English P, Evans J, Mitra D, Todd NV: Intra-operative MRI-assisted spinal localization. Acta Neurochir (Wien) 2010, 152(4):669-73.
- [3]Cornips E, Beuls E, Geskes G, Janssens M, van Aalst J, Hofman P: Preoperative localization of herniated thoracic discs using myelo-CT guided transpleural puncture: technical note. Childs Nerv Syst 2007, 23(1):21-6.
- [4]Binning MJ, Schmidt MH: Percutaneous placement of radiopaque markers at the pedicle of interest for preoperative localization of thoracic spine level. Spine (Phila Pa 1976) 2010, 35(19):1821-5.
- [5]Nowitzke A, Wood M, Cooney K: Improving accuracy and reducing errors in spinal surgery--a new technique for thoracolumbar-level localization using computer-assisted image guidance. Spine J 2008, 8(4):597-604.
- [6]Müller A, Gall C, März U, Reulen HJ: A keyhole approach for endoscopically assisted pedicle screw fixation in lumbar spine instability. Neurosurgery 2000, 47(1):85-95.
- [7]Mroz TE, Abdullah KG, Steinmetz MP, Steinmetz MP, Klineberg EO, Lieberman IH: Radiation Exposure to the Surgeon During Percutaneous Pedicle Screw Placement. J Spinal Disord Tech 2010. Available from: Swets Information Services, Accessed March 24, 2011
- [8]Giordano BD, Baumhauer JF, Morgan TL, Rechtine GR: Cervical spine imaging using standard C-arm fluoroscopy: patient and surgeon exposure to ionizing radiation. Spine (Phila Pa 1976) 2008, 33(18):1970-6.
- [9]Kim TW, Jung JH, Jeon HJ, Yoon KB, Yoon DM: Radiation exposure to physicians during interventional pain procedures. Korean J Pain 2010, 23(1):24-7.
- [10]Delbridge L, Learoyd D: Radiation exposure, thyroid cancer and surgeons. ust N Z J Surg 1998, 68(9):627.
PDF