期刊论文详细信息
Acta Radiologica Short Reports
Successful removal of a Gunther tulip vena cava filter with wall-embedded hook and migration during a retrieval attempt
Takuji Yamagami1  Rika Yoshimatsu1  Tomohiro Matsumoto1  Tsunehiko Nishimura1 
[1] Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural, Kyoto, Japan
关键词: filters;    vena cava;    interventional procedures;    thrombosis;    extremities;    pulmonary;    Embolism;   
Others  :  923803
DOI  :  10.1177/2047981613478010
 received in 2012-08-06, accepted in 2013-01-18,  发布年份 2013
PDF
【 摘 要 】

Retrieval of a Gunther tulip vena cava filter implanted in a patient with inferior vena cava and right common iliac vein thrombosis was attempted by the standard method. Because the filter was tilted, the hook became attached to the vena cava wall and could not be snared. During attempts at removal by an alternative method, the filter migrated toward the right atrium. However, it was finally successfully removed.

【 授权许可】

   
© 2013 The Foundation Acta Radiologica

【 预 览 】
附件列表
Files Size Format View
20140816065404589.pdf 96KB PDF download
Fig. 1 108KB Image download
【 图 表 】

Fig. 1

【 参考文献 】
  • [1]Decousus H, Leizorovics A, Parent F Decousus H, Leizorovics A, Parent F, et al. A clinical trial of vena caval filters in the prevention of pulmonary embolism in patients with proximal deep-vein thrombosis. N Engl J Med 1998;338:409–15
  • [2]Lorch H, Welger D, Wagner V Lorch H, Welger D, Wagner V, et al. Current practice of temporary vena cava filter insertion: a multicenter registry. J Vasc Interv Radiol 2000;11:83–8
  • [3]Neuerburg JM, Gunther RW, Vorwerk D Neuerburg JM, Gunther RW, Vorwerk D, et al. Results of a multicenter study of the retrievable tulip vena cava filter: early clinical experience. Cardiovasc Interv Radiol 1997;20:10–6
  • [4]Kuo WT, Bostaph AS, Loh CT Kuo WT, Bostaph AS, Loh CT, et al. Retrieval of trapped Gunther tulip inferior vena cava filters: snare-one-guide wire loop technique. J Vasc Interv Radiol 2006;17:1845–9
  • [5]Yamagami T, Kato T, Iida S Yamagami T, Kato T, Iida S, et al. Retrievable vena cava filter placement during treatment for deep venous thrombosis. Br J Radiol 2003;76:712–8
  • [6]Millward SF, Bhargava A, Aquino J Jr. Millward SF, Bhargava A, Aquino J Jr., et al. Gunther tulip filter: preliminary clinical experience with retrieval. J Vasc Interv Radiol 2000;11:75–82
  • [7]Yamagami T, Kato T, Hirota T Yamagami T, Kato T, Hirota T, et al. Evaluation of retrievability of the Gunther tulip vena cava filter. Cardiovasc Intervent Radiol 2007;30:226–31
  • [8]Yamagami XX, Kato T, Nishimura T Yamagami XX, Kato T, Nishimura T. Successful retrieval of a Gunther tulip vena cava filter with the assistance of a curved sheath introducer. J Vasc Interv Radiol 2005;16:1760–2
  • [9]Stavropoulos SW, Solomon A, Trerotola SO Stavropoulos SW, Solomon A, Trerotola SO. Well-embedded recovery inferior vena cava filters: imaging features and technique for removal. J Vasc Interv Radiol 2006;17:379–82
  • [10]Bochenek KM, Aruny JE, Tal MG Bochenek KM, Aruny JE, Tal MG. Right atrial migration and percutaneous retrieval of a Gunther tulip inferior vena cava filter. J Vasc Interv Radiol 2003;14:1207–9
  文献评价指标  
  下载次数:21次 浏览次数:9次