期刊论文详细信息
Acta Veterinaria Scandinavica
Individually Coded Telemetry: a Tool for Studying Heart Rate and Behaviour in Reindeer Calves
E Eloranta3  H Norberg2  A Nilsson1  T Pudas2  H Säkkinen2 
[1] Department of Genetics, Swedish University of Agricultural Sciences, Uppsala, Sweden
[2] Department of Biology, University of Oulu, Finland
[3] Department of Physiology, University of Oulu, Finland
关键词: circadian.;    behaviour;    reindeer;    individual coding;    method;    measuring technique;    heart rate;   
Others  :  790186
DOI  :  10.1186/1751-0147-43-135
 received in 2002-04-27, accepted in 2002-05-13,  发布年份 2002
PDF
【 授权许可】

   

【 预 览 】
附件列表
Files Size Format View
20140704205855930.pdf 349KB PDF download
【 参考文献 】
  • [1]Baldock NM, Penning PD, Sibly RM: A system for recording sheep ECG in the field using a miniature 24-h tape recorder. Comput Electron Agric 1987, 2:57-66.
  • [2]Baldock NM, Sibly RM, Penning PD: Behaviour and seasonal variation in heart rate in domestic sheep Ovis aries. Anim Behav 1988, 36:35-43.
  • [3]Collins WB, Smith TS: Twenty-four hour behaviour patterns and budgets of free-ranging reindeer in winter. Rangifer 1989, 9(1):2-8.
  • [4]von Engelhardt W, Hales JRS: Partition of capillary blood flow in rumen, reticulum and omasum of sheep. Am J Physiol 1977, 232:E53-E56.
  • [5]Erkinaro E, Heikura K, Lindgren E, Pulliainen E, Sulkava S: Studies on the daily activity of semi-domestic reindeer (Rangifer tarandus L.) and wild forest reindeer (R. t. fennicus Lönnb.) in eastern Finland. Acta Zool Fennica 1983, 175:29-31.
  • [6]Evans DL, Rose RJ: Method of investigation of the accuracy of four digitally-displaying heart rate meters suitable for use in the exercising horse. Equine Vet J 1986, 18(2):129-132.
  • [7]Fancy SG, White RG: Predicting energy expenditures for activities of caribou from heart rates. Rangifer 1986, (Special Issue1):123-130.
  • [8]Hopster H, Blokhuis HJ: Validation of a heart-rate monitor for measuring a stress response in dairy cows. Can J Anim Sci 1994, 74:465-474.
  • [9]Karvonen J, Chwalbinska-Moneta J, Säynäjäkangas S: Comparison of heart-rates measured by ECG and microcomputer. Physician Sportmed 1984, 12(6):65-69.
  • [10]Kautz MA, Mautz WW, Carpenter LH: Heart rate as a predictor of energy expenditure of mule deer. J Wildl Manage 1981, 45:715-720.
  • [11]MacArthur RA, Johnston RH, Geist V: Factors influencing heart rate in free-ranging bighorn sheep: a physiological approach to the study of wildlife harassment. Can J Zool 1979, 57:2010-2021.
  • [12]Mautz WW, Fair J: Energy expenditure and heart rate for activities of white-tailed deer. J Wildl Manage 1980, 44:333-342.
  • [13]Mesteig K, Tyler NJC, Blix AS: Seasonal changes in heart rate and food intake in reindeer (Rangifer tarandus tarandus). Acta Physiol Scand 2000, 170:145-151.
  • [14]Moen AN: Seasonal changes in heart rates, activity, metabolism, and forage intake of white-tailed deer. J Wildl Manage 1978, 42(4):715-738.
  • [15]Nilssen KJ, Johnsen HK, Rognmo A, Blix AS: Heart rate and energy expenditure in resting and running Svalbard and Norwegian reindeer. Am J Physiol 1984, 246:963-967.
  • [16]Nilsson A, Danell Ö, Murphy M, Olsson K, Åhman B: Health, body condition and blood metabolites in reindeer after submaintenance feed intake and subsequent feeding. Rangifer 2000, 20(4):187-200.
  • [17]Price S, Sibly RM, Davies MH: Effects of behaviour and handling on heart rate in farmed red deer. Appl Anim Behav Sci 1993, 37:111-123.
  • [18]Redbo I, Mossberg I, Ehrlemark A, Ståhl-Högberg M: Keeping growing cattle outside during winter: behaviour, production and climatic demand. Anim Sci 1996, 62:35-41.
  • [19]Sloet van Oldruitenborgh-Oosterbaan MM, Van den Hoven R, Breukink HJ: The accuracy of three different heart-rate meters used for studies in the exercising horse. J Vet Med Ser A 1988, 35:665-672.
  • [20]Seaward BI, Sleamaker RH, McAuliffe T, Clapp JF: The precision and accuracy of a portable heart rate monitor. Biomed Instr Techn 1990, 24:37-41.
  • [21]Timisjärvi J: The blood circulation of the reindeer. Acta Univ Oul D 36 Pharmacol Physiol 1978, 7:45+42.
  • [22]Timisjärvi J, Hirvonen L, Järvensivu P, Nieminen M: Electrocardiogram of the reindeer, Rangifer tarandus tarandus. Laboratory Animals 1979, 13:183-186.
  • [23]Treiber FA, Musante L, Hartdagan S, Davis H, Levy M, Strong WB: Validation of a heart rate monitor with children in laboratory and field settings. Med Sci Sports Exerc 1989, 21(3):338-342.
  • [24]Ähman B, Nilsson A, Eloranta E, Olsson K: Wet-belly in reindeer (Rangifer tarandus tarandus) in relation to body condition, body temperature and blood constituents. Acta Vet Scand, in press.
  文献评价指标  
  下载次数:12次 浏览次数:19次