会议论文详细信息
International Multi-Conference on Industrial Engineering and Modern technologies
Energy and Exergy Analysis of Clinker Cooler in the Cement Industry
Taweel, T.J.B.^1 ; Sokolova, E.^1 ; Sergeev, V.^1 ; Solovev, D.B.^2,3
Peter the Great St. Petersburg Polytechnic University, Polytechnicheskaya 29, Saint Petersburg
195251, Russia^1
Far Eastern Federal University (FEFU), Sukhanov St., 8, Vladivostok
690950, Russia^2
Vladivostok Branch of Russian Customs Academy, Strelkovaya St., 16, Vladivostok
690034, Russia^3
关键词: Clinker cooler;    Clinker cooler systems;    Energy and exergy;    Energy and exergy analysis;    Grate coolers;    Processing units;    Secondary air;    Temperature profiles;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/463/3/032101/pdf
DOI  :  10.1088/1757-899X/463/3/032101
来源: IOP
PDF
【 摘 要 】

Grate coolers which represent one of the pyro-processing units are extensively used in cement industries. The essential function of grate coolers is a waste heat recovery from hot clinker which leaves the rotary kiln. This paper presents an analysis of energy and exergy based on the clinker temperature profile. It focuses on the distributions of temperature, energy and exergy for cooling air and hot clinker along the grate cooler in cement industries. Consequently, this distribution allows predicting the temperatures of secondary air, tertiary air, and exhaust air, which will lead to estimation of waste heat recovery from the clinker cooler system.

【 预 览 】
附件列表
Files Size Format View
Energy and Exergy Analysis of Clinker Cooler in the Cement Industry 337KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:20次