International Conference on Design, Engineering and Computer Sciences 2018 | |
Analysis of Groundwater Quality in an Industrial Location at MM2100 and a Residential Location at Cibuntu, West Java, Indonesia | |
工业技术;计算机科学 | |
Triana, Novera Elisa^1 ; Izzati, Titia^1 ; Hartanto, Aditya^1 | |
Industrial Engineering Program, Universitas Mercu Buana, Jakarta | |
11650, Indonesia^1 | |
关键词: Electrical conductivity; Indonesia; Industrial location; International standards; Quality of water; Residential locations; Total dissolved solids; West javas; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/453/1/012041/pdf DOI : 10.1088/1757-899X/453/1/012041 |
|
来源: IOP | |
【 摘 要 】
The aim of this study is to determine the difference in the quality of groundwater at an industrial location in MM2100 and a residential location, both in Cibuntu, West Java, Indonesia. The parameters used to establish whether or not the water is safe are: standard acidity of the water (pH), total dissolved solid (TDS), and Electrical Conductivity (EC). The results of water tested in MM2100 revealed an average of pH 7-9.7 for acidity, 127.8ppt for total dissolved solid, and 258.5 μS for EC. The results of water tested from the residential location recorded an average of pH 8.0-10 for acidity, 89.4ppt for total dissolved solid, and 179.9 μS for EC. The quality of groundwater for both the industrial and residential locations have been found to be unsafe based on governmental and international standards.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Analysis of Groundwater Quality in an Industrial Location at MM2100 and a Residential Location at Cibuntu, West Java, Indonesia | 853KB | download |