会议论文详细信息
2018 3rd International Conference on Insulating Materials, Material Application and Electrical Engineering | |
Defect Assessment of 3000 M3 Sphere Storage Tank for Propylene | |
材料科学;无线电电子学;电工学 | |
Cai, Gangyi^1,3 ; Xiang, Zhi^1,3 ; Chen, Zhang^1,3 ; Li, Yuebing^2 ; Ye, Yufeng^1,3 | |
Zhejiang Provincial Special Equipment Inspection and Research Institute, Hangzhou, China^1 | |
Institute of Process Equipment and Control Engineering, Zhejiang University of Technology, Hangzhou, China^2 | |
Key Laboratory of Special Equipment Safety Testing Technology of Zhejiang Province, Hangzhou, China^3 | |
关键词: Defect assessment; Domestic standards; Fitness-for-service assessment; Internal surfaces; International standards; Regular inspections; Safety margin; Surface cracks; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/452/2/022139/pdf DOI : 10.1088/1757-899X/452/2/022139 |
|
学科分类:材料科学(综合) | |
来源: IOP | |
![]() |
【 摘 要 】
During the regular inspection of 3000 m3 sphere storage tank for propylene, 15 defects are detected, including 11 internal surface cracks and 4 embed cracks. One of the surface cracks can up to 80mm in length direction. For these defects, the integrity of sphere storage tank with defects is evaluated according to GB/T 19624-2004. To show the difference between the domestic standard and international standards, API 579 is also adopted to perform the Fitness-for-Service assessment. The safety margin is discussed.【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Defect Assessment of 3000 M3 Sphere Storage Tank for Propylene | 196KB | ![]() |