During the regular inspection of 3000 m3 sphere storage tank for propylene, 15 defects are detected, including 11 internal surface cracks and 4 embed cracks. One of the surface cracks can up to 80mm in length direction. For these defects, the integrity of sphere storage tank with defects is evaluated according to GB/T 19624-2004. To show the difference between the domestic standard and international standards, API 579 is also adopted to perform the Fitness-for-Service assessment. The safety margin is discussed.