会议论文详细信息
2018 3rd International Conference on Insulating Materials, Material Application and Electrical Engineering
Research on Closed-loop Start-Up Process of Hydraulic Turbine Based on Adaptive Variable Parameters of Water Head
材料科学;无线电电子学;电工学
Sun, Yang^1 ; Cao, Linning^1 ; Zhou, Haizhou^1
School of Hohai University, Nanjing, China^1
关键词: Conventional pid;    Dynamic adjustment;    Hydro generator;    Hydropower stations;    Performance indices;    Start-up process;    Start-up simulation;    Variable parameters;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/452/4/042007/pdf
DOI  :  10.1088/1757-899X/452/4/042007
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

The large fluctuation range of the operating head of some hydropower stations has an impact on the arrangement of the starting mode. In order to suppress the influence of the water head on the start-up process, a closed-loop start-up simulation model of a hydro-generator unit is established in this paper, and variable parameter control based on head adaptation is adopted. By comparing the performance indexes of the closed-loop start-up process between the conventional PID control and the adaptive variable parameter control, it is shown that the adaptive variable parameter control based on the head has better dynamic adjustment performance.

【 预 览 】
附件列表
Files Size Format View
Research on Closed-loop Start-Up Process of Hydraulic Turbine Based on Adaptive Variable Parameters of Water Head 453KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:23次