会议论文详细信息
2nd Nommensen International Conference on Technology and Engineering
Design and analysis of double pipe counter flow heat exchanger (condenser) to produce hot water as modification of air conditioner split condenser
Napitupulu, Farel H.^1 ; Sabri, M.^1 ; Sihombing, Ferry^1 ; Sihombing, H.V.^1
Mechanical Engineering Department, Faculty of Engineering, Universitas Sumatera Utara, Jl. Almamater, Kampus USU, Medan
20155, Indonesia^1
关键词: Annular pipe;    Coefficient of Performance;    Counter flow heat exchangers;    Counter-flows;    Design and analysis;    Double pipes;    Hot fluid flow;    Vapor compression cycle;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/420/1/012014/pdf
DOI  :  10.1088/1757-899X/420/1/012014
来源: IOP
PDF
【 摘 要 】

This study was conducted to design a heat exchanger double pipe counter flow as a condenser to produce hot water that can be used for various purpose like a warm bath. Hot fluid flows in copper with cold fluid flowing in the annulus. The hot fluid used is R-22 while the cold fluid used is water. This pipe double heat exchanger is measuring 112.04 cm in length by 29 cm in width and 20.3 cm in height. Inside of pipe using copper with diameter 1/4 inch. And total length of the copper pipe 18.915 m. While on the annular pipe using PVC pipe with 1/2 inch size. The total length of the annulus pipe is 16.128 m. In addition, heat exchanger is used to determined heat released by the condenser, coefficient of performance (COP) of vapor compression cycle, efficiency vapor compression cycle and temperature of the condenser-generated hot water.

【 预 览 】
附件列表
Files Size Format View
Design and analysis of double pipe counter flow heat exchanger (condenser) to produce hot water as modification of air conditioner split condenser 185KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:13次