会议论文详细信息
8th International Research-Technical Conference on the Problems of Designing, Construction and Use of Low Energy Housing
Thermal insulation versus overheating - monitoring results
土木建筑工程
Kisilewicz, T.^1
Cracow University of Technology, Institute of Building Materials and Structures, ul. Warszawska 24, Kraków
31-348, Poland^1
关键词: Dynamic characteristics;    Excessive energy;    External walls;    Initial design;    Monitoring results;    Periodic waves;    Source of energy;    Transparent insulations;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/415/1/012033/pdf
DOI  :  10.1088/1757-899X/415/1/012033
学科分类:土木及结构工程学
来源: IOP
PDF
【 摘 要 】

Initial design decisions regarding building external envelope may have important consequences for thermal comfort and total energy demand not only for heating but also for cooling. Before reaching for more energy-intensive solutions, effective use of passive measures to avoid overheating is necessary. In the article, special attention was paid to the influence of external wall structure on space overheating. On the basis of monitoring results it was found that the standard thermal insulation prevented excessive energy conduction into the space on very hot days and it should not be considered as a barrier for heat dissipation. The standard opaque wall was also compared with the uncovered transparent insulation, which is in summer an intensive source of energy gains. The basic dynamic characteristics of the monitored wall were analytically analysed by means of the periodic waves method.

【 预 览 】
附件列表
Files Size Format View
Thermal insulation versus overheating - monitoring results 591KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:35次