会议论文详细信息
2018 5th International Conference on Advanced Composite Materials and Manufacturing Engineering
Study on the Performance of the Fluidic Calibration Device of PM2.5 Mass Concentration Monitor
Zou, Junchen^1 ; Zou, Xiaohua^1 ; Fan, Wei^1 ; Zhang, Wuqiang^2 ; Fan, Zhenxing^1 ; He, Liren^1 ; Liu, Xiuxiu^1 ; Shi, Huimin^3 ; Shi, Yiwen^3
Henan Institute of Metrology, Zhengzhou, China^1
Ruan Center of Quality Technical Supervision and Inspection, Zhumadian, China^2
Langyi Electromechanical Equipment Co. Ltd., Zhangjiagang, China^3
关键词: Dust concentrations;    Low concentrations;    PM2.5 mass;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/394/5/052073/pdf
DOI  :  10.1088/1757-899X/394/5/052073
来源: IOP
PDF
【 摘 要 】

A fluidic calibration device of PM2.5 mass concentration monitor was developed successfully, its components were introduced and its properties were evaluated. The result showed that the designed concentration was highly consistent with the actual dust concentration, and the repeatability of the calibration device was less than 5%, and the uniformity of the calibration device was less than 7%, it indicated that the calibration device had a huge advantage in calibrating the PM2.5 monitor at low concentration of (25-75) μg/m3.

【 预 览 】
附件列表
Files Size Format View
Study on the Performance of the Fluidic Calibration Device of PM2.5 Mass Concentration Monitor 828KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:25次