会议论文详细信息
25th International Conference on Vacuum Technique and Technology
Phase difference meter between the alternating current and voltage components for determining the impedance of plasma of glow discharge lasers
Kiselev, A.S.^1 ; Smirnov, E.A.^1 ; Fadeev, A.S.^1
Department of Electronic Instruments and Devices, Saint Petersburg Electrotechnical University LETI, Saint Petersburg
197376, Russia^1
关键词: Alternating current;    Discharge currents;    Dynamic resistance;    Harmonic signals;    Phase difference;    Rectangular pulse;    Time shifts;    Voltage drop;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/387/1/012036/pdf
DOI  :  10.1088/1757-899X/387/1/012036
来源: IOP
PDF
【 摘 要 】

In this work meter for the phase difference of the variable components of the discharge current and the voltage drop was developed and tested. The operation of the meter is based on the transformation of harmonic signals into rectangular pulses, and further determination of the time shift between them. The possibility of using this meter for monitoring the dynamic resistance of glow discharge lasers is shown.

【 预 览 】
附件列表
Files Size Format View
Phase difference meter between the alternating current and voltage components for determining the impedance of plasma of glow discharge lasers 599KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:26次