| 2018 International Conference on Material Strength and Applied Mechanics | |
| An experimental study on the shear strength of FRP perfobond shear connector | |
| 材料科学;力学 | |
| Gwon, S.C.^1 ; Kim, S.H.^1 ; Yoon, S.J.^2 ; Choi, C.W.^1 | |
| Department of Architectural Engineering, Gachon University, 1342 Seongnam daero, Sujeong-gu, Gyeonggi-do | |
| 13120, Korea, Republic of^1 | |
| Department of Civil Engineering, Hongik University, 94 Wausan-ro, Mapo-gu, Seoul | |
| 04066, Korea, Republic of^2 | |
| 关键词: Dowel effect; Frictional effects; Frictional resistance; Push-out tests; Shear behaviour; Shear capacity; Shear connector; Shear resistances; | |
| Others : https://iopscience.iop.org/article/10.1088/1757-899X/372/1/012042/pdf DOI : 10.1088/1757-899X/372/1/012042 |
|
| 来源: IOP | |
PDF
|
|
【 摘 要 】
In this study, push-out tests were conducted to investigate shear behaviour of FRP perfobond shear connector. The parameters influencing shear capacity of FRP perfobond shear connector are concrete dowel effect, shear resistance effect of the laterally reinforced FRP re- bar, and frictional effect between shear connector and concrete. The specimens were designed to consider these parameters. The specimens coated with sand to increase frictional resistance between the FRP re-bar and concrete. Based on the test results and the parameters, new equation was suggested to predict shear strength of FRP perfobond shear connectors. The predicted results and the experimental results were compared to check the feasibility of prediction.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| An experimental study on the shear strength of FRP perfobond shear connector | 523KB |
PDF