2nd International Conference on Oleo and Petrochemical Engineering | |
Application of Response Surface Methodology (RSM) for wastewater of hospital by using electrocoagulation | |
Murdani^1 ; Jakfar^2 ; Ekawati, D.^2 ; Nadira, R.^2 ; Darmadi^2 | |
Chemical Engineering Master Program, Syiah Kuala University, Banda Aceh, Indonesia^1 | |
Chemical Engineering Department, Syiah Kuala University, Banda Aceh, Indonesia^2 | |
关键词: Aluminum electrodes; Concentration electrolyte; Electro coagulations; ELectrochemical methods; Environmental contamination; Hospital wastewater; Independent variables; Response surface methodology; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/345/1/012011/pdf DOI : 10.1088/1757-899X/345/1/012011 |
|
来源: IOP | |
【 摘 要 】
Hospital wastewater is a source of potential environmental contamination. Therefore, the waste water needs to be treated before it is discharged into the landfill. Various research methods have been used to treat hospital wastewater. However, some methods that have been implemented have not achieved the effluent standards for hospitals that have been set by the government. The experiment was conducted by an electrochemical method is electrolysis using aluminum electrodes with independent variable is the voltage, contact time and concentration of electrolytes. The response optimization using response surface with optimum conditions obtained by the contact time of 34.26 min, voltage 12 V, concentration electrolyte 0.38 M can decrease of COD 65.039%. The model recommended by the response surface for the three variables, namely quadratic response.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Application of Response Surface Methodology (RSM) for wastewater of hospital by using electrocoagulation | 308KB | download |