International Nuclear Science, Technology and Engineering Conference 2017 | |
Analysis of Water Volume Changes and Temperature Measurement Location Effect to the Accuracy of RTP Power Calibration | |
原子能学 | |
Lanyau, T.^1 ; Hamzah, N.S.^1 ; Jalal Bayar, A.M.^1 ; Abdul Karim, J.^1 ; Phongsakorn, P.K.^1 ; Mohammad Suhaimi, K.^1 ; Hashim, Z.^1 ; Md Razi, H.^1 ; Mohd Fazli, Z.^1 ; Ligam, A.S.^1 ; Mustafa, M.K.A.^1 | |
Malaysian Nuclear Agency, Bangi Selangor Kajang | |
43000, Malaysia^1 | |
关键词: Calorimetric methods; Location effects; Measurement locations; Power calibration; Safe operation; Temperature trends; Variation of water level; Water temperatures; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/298/1/012032/pdf DOI : 10.1088/1757-899X/298/1/012032 |
|
来源: IOP | |
【 摘 要 】
Power calibration is one of the important aspect for safe operation of the reactor. In RTP, the calorimetric method has been applied in reactor power calibration. This method involves measurement of water temperature in the RTP tank. Water volume and location of the temperature measurement may play an important role to the accuracy of the measurement. In this study, the analysis of water volume changes and thermocouple location effect to the power calibration accuracy has been done. The changes of the water volume are controlled by the variation of water level in reactor tank. The water level is measured by the ultrasonic measurement device. Temperature measurement has been done by thermocouple placed at three different locations. The accuracy of the temperature trend from various condition of measurement has been determined and discussed in this paper.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Analysis of Water Volume Changes and Temperature Measurement Location Effect to the Accuracy of RTP Power Calibration | 412KB | download |