8th TSME-International Conference on Mechanical Engineering | |
Performance characteristic of hybrid cooling system based on cooling pad and evaporator | |
Yoon, J.I.^1 ; Son, C.H.^1 ; Choi, K.H.^1 ; Kim, Y.B.^1 ; Sung, Y.H.^2 ; Roh, S.J.^2 ; Kim, Y.M.^3 ; Seol, S.H.^4 | |
Pukyong National University, Busan | |
48547, Korea, Republic of^1 | |
Pukyong National University Graduate School, Busan | |
48547, Korea, Republic of^2 | |
JUNG in HI-TECH, Ulsan | |
44716, Korea, Republic of^3 | |
Hokkaido University, N13-W8, Kita Ku, Sapporo | |
060-328, Japan^4 | |
关键词: Conventional air-conditioning systems; Economical operation; Evaporative coolers; Evaporative cooling pads; Experimental analysis; Installation costs; Performance characteristics; Total power consumption; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/297/1/012070/pdf DOI : 10.1088/1757-899X/297/1/012070 |
|
来源: IOP | |
【 摘 要 】
In South Korea, most of domestic animals such as pigs and chickens might die due to thermal diseases if they are exposed to the high temperature consistently. In order to save them from the heat wave, numerous efforts have been carried out: installing a shade net, adjusting time of feeding, spraying mist and setting up a circulation fan. However, these methods have not shown significant improvements. Thus, this study proposes a hybrid cooling system combining evaporative cooler and air-conditioner in order to resolve the conventional problems caused by the high temperature in the livestock industry. The problem of cooling systems using evaporative cooling pads is that they are not effective for eliminating huge heat load due to their limited capacity. And, temperature of the supplied air cannot be low enough compared to conventional air-conditioning systems. On the other hand, conventional air-conditioning systems require relatively expensive installation cost, and high operating cost compared to evaporative cooling system. The hybrid cooling system makes up for the lack of cooling capacity of the evaporative cooler by employing the conventional air-conditioner. Additionally, temperature of supplied air can be lowered enough. In the hybrid cooling system, induced air by a fan is cooled by the evaporation of water in the cooling pad, and it is cooled again by an evaporator in the air-conditioner. Therefore, the more economical operation is possible due to additionally obtained cooling capacity from the cooling pads. Major results of experimental analysis of hybrid cooling system are as follows. The compressor power consumption of the hybrid cooling system is about 23% lower, and its COP is 17% higher than that of the conventional air-conditioners. Regarding the condition of changing ambient temperature, the total power consumption decreased by about 5% as the ambient temperature changed from 28.7°C to 31.7°C. Cooling capacity and COP also presented about 3% and 1% of minor difference at the same comparison condition.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Performance characteristic of hybrid cooling system based on cooling pad and evaporator | 817KB | download |