International Conference on Applied Sciences 2017 | |
Determination of the wind power systems load to achieve operation in the maximum energy area | |
Chioncel, C.P.^1 ; Tirian, G.O.^2 ; Spunei, E.^1 ; Gillich, N.^1 | |
Eftimie Murgu University of Resita, Department of Electrical Engineering and Informatics, Traian Vuia str., no. 3-4, Resita | |
320085, Romania^1 | |
Politehnica University of Timisoara, Department of Electrical Engineering and Industrial Informatics, 5 Revolution Street, Hunedoara | |
331128, Romania^2 | |
关键词: Angular speed; Constant values; Control methods; Maximum power point; Optimum performance; Paper analysis; Permanent magnet synchronous generator; Time variations; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/294/1/012091/pdf DOI : 10.1088/1757-899X/294/1/012091 |
|
来源: IOP | |
【 摘 要 】
This paper analyses the operation of the wind turbine, WT, in the maximum power point, MPP, by linking the load of the Permanent Magnet Synchronous Generator, PMSG, with the wind speed value. The load control methods at wind power systems aiming an optimum performance in terms of energy are based on the fact that the energy captured by the wind turbine significantly depends on the mechanical angular speed of the wind turbine. The presented control method consists in determining the optimal mechanical angular speed, ωOPTIM, using an auxiliary low power wind turbine, WTAUX, operating without load, at maximum angular velocity, ωMAX. The method relies on the fact that the ratio ωOPTIM/ωMAXhas a constant value for a given wind turbine and does not depend on the time variation of the wind speed values.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Determination of the wind power systems load to achieve operation in the maximum energy area | 540KB | download |