会议论文详细信息
Cryogenic Engineering Conference 2017
Attenuation of cryocooler induced vibration using multimodal tuned dynamic absorber
材料科学;物理学
Veprik, A.^1 ; Babitsky, V.^2 ; Tuito, A.^3
SemiConductor Devices, POB 2250, Haifa
31021, Israel^1
Loughborough University, Epinal Way, Loughborough
LE11 3TU, United Kingdom^2
Israel MOD, Kirya, Tel Aviv
64734, Israel^3
关键词: Driving frequencies;    Dynamic absorber;    Dynamic reactions;    Full-scale testing;    Induced vibrations;    Infrared imagers;    Modal frequency;    Translational dynamics;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/278/1/012005/pdf
DOI  :  10.1088/1757-899X/278/1/012005
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

Modern infrared imagers often rely on low Size, Weight and Power split Stirling linear cryocoolers comprised of side-by-side packed compressor and expander units fixedly mounted upon a common frame and interconnected by the configurable transfer line. Imbalanced reciprocation of moving assemblies generates vibration export in the form of tonal force couple producing angular and translational dynamic responses. Resulting line of sight jitter and dynamic defocusing may affect the image quality. The authors explore the concept of multimodal tuned dynamic absorber, the translational and tilting modal frequencies of which are essentially matched to the driving frequency. Dynamic analysis and full-scale testing show that the dynamic reactions (forces and moments) produced by such a device may effectively attenuate both translational and angular components of cryocooler-induced vibration.

【 预 览 】
附件列表
Files Size Format View
Attenuation of cryocooler induced vibration using multimodal tuned dynamic absorber 1449KB PDF download
  文献评价指标  
  下载次数:21次 浏览次数:37次