Cryogenic Engineering Conference 2017 | |
Experimental investigation on charcoal adsorption for cryogenic pump application | |
材料科学;物理学 | |
Scannapiego, Matthieu^1 ; Day, Christian^1 | |
Institute for Technical Physics, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopolshafen | |
76344, Germany^1 | |
关键词: Experimental investigations; Gas flow conditions; Hydrogen isotope; Panel temperature; Pump configuration; Separation functions; Sticking coefficients; Tritium inventory; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/278/1/012160/pdf DOI : 10.1088/1757-899X/278/1/012160 |
|
学科分类:材料科学(综合) | |
来源: IOP | |
【 摘 要 】
Fusion reactors are generating energy by nuclear fusion between deuterium and tritium. In order to evacuate the high gas throughputs from the plasma exhaust, large pumping speed systems are required. Within the European Fusion Programme, the Karlsruhe Institute of Technology (KIT) has taken the lead to design a three-stage cryogenic pump that can provide a separation function of hydrogen isotopes from the remaining gases; hence limiting the tritium inventory in the machine. A primary input parameter for the detailed design of a cryopump is the sticking coefficient between the gas and the pumping surface. For this purpose, the so-called TIMO open panel pump experiment was conducted in the TIMO-2 test facility at KIT in order to measure pumping speeds on an activated carbon surface cooled at temperatures between 6 K and 22 K, for various pure gases and gas mixtures, under fusion relevant gas flow conditions, and for two different geometrical pump configurations. The influences of the panel temperature, the gas throughput and the intake gas temperature on the pumping speed have been characterized, providing valuable qualitative results for the design of the three-stage cryopump. In a future work, supporting Monte Carlo simulations should allow for derivation of the sticking coefficients.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Experimental investigation on charcoal adsorption for cryogenic pump application | 893KB | download |