Cryogenic Engineering Conference 2017 | |
Force cooled quench tanks for the ITER cryogenic system | |
材料科学;物理学 | |
Kouzmenko, G.^1 ; Simon, M.^1 ; Saulquin, S.^1 ; Buskop, J.^2 ; Voigt, T.^2 ; Monneret, E.^2 ; Grillot, D.^2 ; Cursan, M.^2 ; Pichot, D.^3 ; Demar, G.^3 | |
Fusion for Energy, C/ Josep Pla 2, Barcelona | |
08019, Spain^1 | |
ITER Organization, Route de Vinon-sur-Verdon, St. Paul-lez-Durance | |
13067, France^2 | |
Air Liquide Global EandC Solutions (France), 57 Avenue Carnot, Champigny-sur-Marne | |
94500, France^3 | |
关键词: Appropriate technologies; Cryogenic system; Gas circulation; Input datas; Quench tanks; Storage vessel; Toroidal-field magnets; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/278/1/012109/pdf DOI : 10.1088/1757-899X/278/1/012109 |
|
学科分类:材料科学(综合) | |
来源: IOP | |
【 摘 要 】
The toroidal field magnets of ITER contain over 7 tons of helium. Most of the inventory is expelled from the magnets in case of a quench and it needs to be captured in external storage vessels (Quench Tanks). Force cooled technology with external gas circulation was chosen for these vessels in order to optimize their footprint, risks, and costs. This paper outlines the input data, assumptions, and studies performed in order to choose the most appropriate technology for the Quench Tanks. Further studies to demonstrate feasibility and ensure the required performance, as well as some peculiarities of the design and manufacturing of Quench Tanks are also described.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Force cooled quench tanks for the ITER cryogenic system | 499KB | download |