Cryogenic Engineering Conference 2017 | |
Cool down time optimization of the Stirling cooler | |
材料科学;物理学 | |
Xia, M.^1 ; Chen, X.P.^1 ; Li, H.Y.^1 ; Gan, Z.H.^2 | |
Department of Infrared Detector, Kunming Institute of Physics, Kunming | |
650217, China^1 | |
Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou | |
310027, China^2 | |
关键词: Cooling power; Cryogenic coolers; Down time; Input power; Stainless steel mesh; Stirling; Stirling coolers; Thermal mass; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/278/1/012043/pdf DOI : 10.1088/1757-899X/278/1/012043 |
|
学科分类:材料科学(综合) | |
来源: IOP | |
【 摘 要 】
The cooling power is one of the most important performances of a Stirling cooler. However, in some special fields, the cool down time is more important. It is a great challenge to improve the cool down time of the Stirling cooler. A new split Stirling linear cryogenic cooler SCI09H was designed in this study. A new structure of linear motor is used in the compressor, and the machine spring is used in the expander. In order to reduce the cool down time, the stainless-steel mesh of regenerator is optimized. The weight of the cooler is 1.1 kg, the cool down time to 80K is 2 minutes at 296K with a 250J thermal mass, the cooling power is 1.1W at 80K, and the input power is 50W.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Cool down time optimization of the Stirling cooler | 560KB | download |