会议论文详细信息
International Conference of Applied Science and Technology for Infrastructure Engineering
Odua Weston Jambi Hotel's Structural Building Design with Prestressed Concrete Slab System Approach
土木建筑工程;材料科学
Bayuaji, R.^1 ; Darmawan, M.S.^1 ; Rofiq, M.A.^1 ; Santoso, S.E.^1 ; Hardiyanto, E.^1
Department of Civil Infrastructure Engineering Institut Teknologi Sepuluh Nopember Indonesia, Indonesia^1
关键词: Conventional concrete;    Pre-stressed concrete slab;    Special moment-resisting frames;    Structural beams;    Structural buildings;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/267/1/012021/pdf
DOI  :  10.1088/1757-899X/267/1/012021
来源: IOP
PDF
【 摘 要 】

Odua Weston Jambi Hotel is an eight-floor hotel and located in a prone to earth-quake area. This building used conventional concrete to its structural beam and column. This research's purpose was to maximize the second-floor's function by modifing its architectural design. Special Moment Resisting Frame System (SMRFS) approach was used in the structural design, referred to SNI 03-2847-2013 dan SNI 1726-2012 and to compensate the needs of a spacious hall without any column in the centre of the hall, so therefore, prestressed concrete plate is used to solve this problem.

【 预 览 】
附件列表
Files Size Format View
Odua Weston Jambi Hotel's Structural Building Design with Prestressed Concrete Slab System Approach 1329KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:22次