会议论文详细信息
International Conference on Construction, Architecture and Technosphere Safety 2017
Laboratory Tests for Dispersive Soil Viscosity Determining
土木建筑工程
Ter-Martirosyan, Z.G.^1 ; Ter-Martirosyan, A.Z.^1 ; Sobolev, E.S.^1
Department of Soil Mechanics and Geotechnics, Moscow State University of Civil Engineering (National Research University), Yaroslavskoye Shosse, 26, Moscow
129337, Russia^1
关键词: Dispersive soils;    Experimental verification;    Laboratory test;    Moscow State University;    New devices;    Shear tests;    Test apparatus;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/262/1/012101/pdf
DOI  :  10.1088/1757-899X/262/1/012101
学科分类:土木及结构工程学
来源: IOP
PDF
【 摘 要 】
There are several widespread methods for soil viscosity determining now. The standard shear test device and torsion test apparatus are the most commonly used installations to do that. However, the application of them has a number of disadvantages. Therefore, the specialists of Moscow State University of Civil Engineering proposed a new device to determine the disperse soil viscosity on the basis of a stabilometer with the B-type camera (viscosimeter). The paper considers the construction of a viscosimeter and the technique for determining soil viscosity inside this tool as well as some experimental verification results of its work.
【 预 览 】
附件列表
Files Size Format View
Laboratory Tests for Dispersive Soil Viscosity Determining 1745KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:23次