Justification of Natural Lighting Management for Workplaces with Displays
土木建筑工程
Kudryashov, A.V.^1 ; Erunova, A.V.^1 ; Kalinina, A.S.^1
Health and Safety Department, South Ural State University, Lenin Avenue, 76, Chelyabinsk
454080, Russia^1
关键词: Artificial lighting;    Lighting controls;    Measurements of;    Natural illumination;    Natural light;    Natural lighting;    Normalized values;    Time control;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/262/1/012092/pdf
DOI  :  10.1088/1757-899X/262/1/012092
学科分类:土木及结构工程学
来源: IOP
PDF
【 摘 要 】

The article is devoted to the study of the influence of the orientation of light apertures (windows) on the distribution of illumination in a room inside the workplaces equipped with displays. The measurements of natural light were carried out in two similar rooms, in the first room the windows are oriented to the north and in the second - to the south. The normative illumination value in a workplace equipped with a personal computer or display must be between 300 and 500 lux. However, during the daytime, the value of natural illumination at the workplace can exceed the normalized value by several times, and in the morning and evening hours is not sufficient. Such distribution of illumination involves the use a combined lighting control system (with daylight time control and switching on artificial lighting in the morning and evening hours). In the article it is justified that the orientation of the windows in the room does not have a significant effect on the distribution of illumination throughout the room which makes it possible not to take into account the restrictions concerning the orientation of the room's light apertures when combined lighting control systems are used.

【 预 览 】
附件列表
Files Size Format View
Justification of Natural Lighting Management for Workplaces with Displays 2831KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:25次