World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium - WMCAUS | |
Indoor Noise Loading in Residential Prefabricated Buildings | |
土木建筑工程 | |
Kraus, Michal^1 ; Juhásová Šenitková, Ingrid^1 | |
Institute of Technology and Business in eské Budjovice, Department of Civil Engineering, Okruní 517/10, eské Budjovice | |
370 01, Czech Republic^1 | |
关键词: Correction coefficients; High pressure laminates; Hydraulic shocks; Indoor environment; Maximum noise levels; Sanitary systems; Specific problems; Water distributions; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/245/8/082028/pdf DOI : 10.1088/1757-899X/245/8/082028 |
|
学科分类:土木及结构工程学 | |
来源: IOP | |
【 摘 要 】
Quality on indoor environment is among others also defined by an acoustic comfort and noise emissions. The indoor noise loading in the residential prefabricated buildings is specific problem related to structural design of these buildings. Problems with noise level of sanitary systems are mostly associated with hydraulic shock such as water distribution and sewage drainage. Another very common cause of excessive noise is also flushing the toilet or water fall on enamelled steel (bath or shower). This paper aims to analyse the acoustic properties in the residential prefabricated buildings. Sanitary core of the assessed apartment is in original condition without any alterations. The sanitary core is based on a formica (high-pressure laminate). The study discusses the maximum sound levels in the three assessed rooms for the three different noise sources. The values of maximum noise level are measured for the corridor, bedroom and living room. Sources of noise are common activities relating to the operation of sanitary core - the toilet flush in the toilet, falling water from the shower in the bathroom and the water falling on the bottom of the kitchen sink in the kitchen. Other sources of noise are eliminated or minimized during the experiment. The digital sound level meter Testo 815 is used for measurements. The measured values of maximum sound level LA,max [dB] are adjusted by the correction coefficient. The obtained values are compared with the hygienic limits for day and night period. Night hygienic limit (30 dB) is exceeded in all the rooms for all noise sources. This limit is exceeded from 17 to 73%. The values in the bedroom and the living room meet the daily hygienic limit (40 dB). The daily limit is exceeded only in the corridor. The highest values of noise are identified for the toilet flushing.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Indoor Noise Loading in Residential Prefabricated Buildings | 619KB | download |