| International Conference on Materials, Alloys and Experimental Mechanics 2017 | |
| Experimental Investigation of COP Using Hydro Carbon Refrigerant in a Domestic Refrigerator | |
| 材料科学;金属学;机械制造 | |
| Peyyala, Anusha^1 ; Sudheer, N.V.V.S.^2 | |
| Mechanical Engineering Department, P v P Siddhartha Institute of Technology, Vijayawada, India^1 | |
| Mechanical Engineering Department, R v R and J C College of Engineering, Guntur, India^2 | |
| 关键词: Coefficient of Performance; Domestic refrigerators; Eco-friendly; Experimental investigations; Global warming potential; Hydrochlorofluorocarbons; Non-conventional energy sources; Ozone depleting potentials; | |
| Others : https://iopscience.iop.org/article/10.1088/1757-899X/225/1/012236/pdf DOI : 10.1088/1757-899X/225/1/012236 |
|
| 学科分类:材料科学(综合) | |
| 来源: IOP | |
PDF
|
|
【 摘 要 】
Under the Montreal protocol 1987 researchers worked on the possibility of alternative refrigerants like Hydroflourocarbon's [HFC's] and Hydrocarbon's[HC's] to replace refrigerants Chloroflourocarbon's [CFC's] and Hydrochlorofluorocarbons [HCFC's] in air-conditioning and cooling systems that are destroying the ozone layer. On October 15, 2016 one hundred and ninety plus countries including India came to an agreement called Kigali Amendment to phase out potent green house gases by 2045 there by preventing 0.5 C rise in global temperature by 2050. Under this agreement India agreed to a timeline to reduce the use of HFC's by 85% of their baseline by 2045. HFC's are a family of greenhouse gases that are largely used in refrigerators and air conditioners which have reduced the Ozone Depleting Potential [ODP] but increased the Global Warming Potential [GWP]. Refrigeration and its applications are important in almost all branches of industry, so engineers have to become aware of its principles, uses and limitations. Since the decade there are major changes in the choice of refrigerants due to environmental factors. This issue is on-going and new developments should be developed to decrease the environmental problems. So the aim of this paper is to present the experimental analysis of Coefficient of performance [COP] values using R134a [HFC] & R600a [HC] as Refrigerants in Domestic refrigerator using conventional and nonconventional energy sources. Based on the results, usage of R600a in domestic refrigerators will reduce the ODP and also GWP problems which fulfills the nominal requirements of human beings without any effects.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| Experimental Investigation of COP Using Hydro Carbon Refrigerant in a Domestic Refrigerator | 2405KB |
PDF