Innovative Ideas in Science 2016 | |
Fuzzy control strategy for secondary cooling of continuous steel casting | |
Tirian, G.O.^1 ; Gheorghiu, C.A.^2 ; Hepu, T.^2 ; Rob, R.^1 | |
Politehnica University of Timisoara, Electrical Engineering and Industrial Informatics Department, 5 Revolution Street, Hunedoara | |
331128, Romania^1 | |
Politehnica University of Timisoara, Department of Engineering and Management, 5 Revolution Street, Hunedoara | |
331128, Romania^2 | |
关键词: Arcelor; Continuous steel casting; Decision rules; Degree of risks; Existing structure; Fuzzy control strategy; Fuzzy database; Secondary cooling; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/200/1/012046/pdf DOI : 10.1088/1757-899X/200/1/012046 |
|
来源: IOP | |
【 摘 要 】
The purpose of this paper is to create an original fuzzy solution on the existing structure of the control system of continuous casting that eliminates fissures in the poured material from the secondary cooling of steel. For this purpose a system was conceived with three fuzzy database decision rules, which by analyzing a series of measurements taken from the process produces adjustments in the rate of flow of the cooling water and the speed of casting and determine the degree of risk of the wire. In the specialized literature on the national plan and the world, there is no intelligent correction in the rate of flow of the cooling water and the speed of casting in the secondary cooling of steel. The database of rules was made using information collected directly from the installation process of continuous casting of the Arcelor Mittal Hunedoara.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Fuzzy control strategy for secondary cooling of continuous steel casting | 1042KB | download |