会议论文详细信息
Frontiers in Automobile and Mechanical Engineering
Comparative Study of Fault Diagnostic Methods in Voltage Source Inverter Fed Three Phase Induction Motor Drive
Dhumale, R.B.^1 ; Lokhande, S.D.^1
Department of Electronics and Telecommunication, Sinhgad College of Engineering, Pune, India^1
关键词: Comparative studies;    Experimental set up;    Fault diagnostic methods;    Metal oxide field effect transistors;    Pulse width modulation inverters;    Short-circuit fault;    Three phase induction motor drives;    Voltage source inverter;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/197/1/012006/pdf
DOI  :  10.1088/1757-899X/197/1/012006
来源: IOP
PDF
【 摘 要 】

Three phase Pulse Width Modulation inverter plays vital role in industrial applications. The performance of inverter demeans as several types of faults take place in it. The widely used switching devices in power electronics are Insulated Gate Bipolar Transistors (IGBTs) and Metal Oxide Field Effect Transistors (MOSFET). The IGBTs faults are broadly classified as base or collector open circuit fault, misfiring fault and short circuit fault. To develop consistency and performance of inverter, knowledge of fault mode is extremely important. This paper presents the comparative study of IGBTs fault diagnosis. Experimental set up is implemented for data acquisition under various faulty and healthy conditions. Recent methods are executed using MATLAB-Simulink and compared using key parameters like average accuracy, fault detection time, implementation efforts, threshold dependency, and detection parameter, resistivity against noise and load dependency.

【 预 览 】
附件列表
Files Size Format View
Comparative Study of Fault Diagnostic Methods in Voltage Source Inverter Fed Three Phase Induction Motor Drive 824KB PDF download
  文献评价指标  
  下载次数:4次 浏览次数:17次