会议论文详细信息
| 5th International Conference: Modern Technologies For Non-Destructive Testing | |
| High-Energy X-ray Radiation Registration Model | |
| 材料科学;物理学 | |
| Osipov, S.P.^1 ; Osipov, O.S.^2 ; Ignatenko, K.V.^1 | |
| National Research Tomsk Polytechnic University, Tomsk, Russia^1 | |
| Company Solveig Multimedia, Tomsk, Russia^2 | |
| 关键词: Absorbed energy; Computing Experiments; Developed model; High energy X ray; Imitation models; Mean values; X ray photons; | |
| Others : https://iopscience.iop.org/article/10.1088/1757-899X/189/1/012035/pdf DOI : 10.1088/1757-899X/189/1/012035 |
|
| 学科分类:材料科学(综合) | |
| 来源: IOP | |
PDF
|
|
【 摘 要 】
It is proved the necessity for carrying out computing experiments according to the mean value and the square of registered X-ray photons absorbed energy of in a scintillation detector. The offered imitation model of the transfer and registration of high-energy X-ray radiation in a sensing volume of CsI and CdWO4scintillation detectors is based on a Monte Carlo method. The model considers leakage of secondary photons and electrons. It is offered approaches to justification of adequacy of the developed model of a high-energy X-ray radiation registration.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| High-Energy X-ray Radiation Registration Model | 775KB |
PDF