会议论文详细信息
5th International Conference: Modern Technologies For Non-Destructive Testing
Soil ph Control in the Mobile Corrosion Monitoring
材料科学;物理学
Radenkov, T.A.^1 ; Romanenko, S.V.^1 ; Kolpakov, V.A.^1 ; Merzlyakov, O.E.^2 ; Kabanov, V.A.^1 ; Kagirov, A.G.^1
Tomsk Polytechnic University, Tomsk, Russia^1
Tomsk State University, Tomsk, Russia^2
关键词: Corrosion monitoring;    Corrosion reaction;    Hydrogen absorption;    Measuring device;    Pipe material;    Pipeline installation;    Sampling points;    Soil pH;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/189/1/012030/pdf
DOI  :  10.1088/1757-899X/189/1/012030
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

Corrosion monitoring methods and pH measuring devices are studied. Considering the heterogeneity of the soil pH, depending on depth and sampling points, it is advisable to use solid-state potentiometric sensors that are capable of pH measuring with an error not exceeding 0.2 pH units. In the process of the pipeline installation necessary to control the soil pH value. While it is impossible to predict what kind of horizon will be in contact with the pipe material at different points. This problem requires future development of technique for the correct pH measuring for the purpose of mobile pipeline corrosion monitoring. When using cathodic protection has been required find the balance between the parameters which prevent the corrosion reactions and also take into account the hydrogen absorption on surface of the pipes material.

【 预 览 】
附件列表
Files Size Format View
Soil ph Control in the Mobile Corrosion Monitoring 701KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:31次