1st Annual Applied Science and Engineering Conference | |
Mapping Air Quality Index of Carbon Monoxide (CO) in Medan City | |
工业技术;自然科学 | |
Suryati, I.^1 ; Khair, H.^1 | |
Environmental Engineering, University of Sumatera Utara, Jl Almamater, Medan | |
20155, Indonesia^1 | |
关键词: Air quality indices; Average concentration; CO concentrations; Government regulation; Meteorological factors; National ambient air quality standards; Sampling points; Sampling tools; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/180/1/012114/pdf DOI : 10.1088/1757-899X/180/1/012114 |
|
来源: IOP | |
【 摘 要 】
This study aims to map and analyze air quality index of carbon monoxide (CO) in Medan City. This research used 12 (twelve) sampling points around in Medan with an hour duration each point. CO concentration was analyzed using the NDIR CO Analyzer sampling tool. The concentration CO was obtained between 1 ppm - 23 ppm, with an average concentration was 9.5 ppm. This condition is still below the national ambient air quality standard set by Government Regulation of Indonesian Republic Number 41-1999 amounted to 29 ppm. The result of CO concentration measurements was converted into air pollutant standard index, obtained the index value of 58 - 204. Surfer 10 was used to create map of air pollutant standard index for CO. The map illustrates very unhealthy area where located in the Medan Belawan district. The main factors affecting the concentration of CO are from transportation and meteorological factors.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Mapping Air Quality Index of Carbon Monoxide (CO) in Medan City | 752KB | download |