会议论文详细信息
26th International Cryogenic Engineering Conference & International Cryogenic Materials Conference 2016
Acceptance tests and their results for 1st Pre-Series Cryoline (PTCL) of ITER
材料科学;物理学
Kapoor, H.^1 ; Garg, A.^1 ; Shah, N.^1 ; Muralidhara, S.^1 ; Choukekar, K.^1 ; Dash, B.^1 ; Gaur, V.^1 ; Madeenavalli, S.^1 ; Patel, P.^1 ; Kumar, U.^1 ; Jadon, M.^1 ; Shukla, V.^1 ; Sarkar, B.^1 ; Sarvaiya, Y.^1 ; Mukherjee, D.^2 ; Dutta, A.^2 ; Murugan, K.V.^2 ; Gajera, S.^2 ; Joshi, B.^2 ; Panjwani, R.^2
ITER-India, Institute for Plasma Research, Bhat, Gandhinagar
382428, India^1
Inox India Private Limited, Vadodara, India^2
关键词: Critical location;    Displacement sensor;    Instrumentation installation;    Measurement of temperature;    Mechanical integrity;    Primary objective;    Thermal Performance;    Thermal shields;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/171/1/012054/pdf
DOI  :  10.1088/1757-899X/171/1/012054
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

The Pre-Series Cryoline (PTCL) for ITER is a representative cryoline from the complicated network of all cryolines for the ITER project. It is ∼28 m in length with same cross-section (1:1) including main line (ML) and branch line (BL) as of ITER torus & cryostat cryoline. Geometrically; it has bends at different angles i.e. 90°, 120°, 135° & 160° comprising T-section & Z-section. The PTCL has been fabricated in 5 different elements based on the installation feasibility. The mechanical & instrumentation installation like sensors mounting, displacement sensors, etc. has been completed. The PTCL test has been performed after complete installation of PTCL and integration with the existing test facility at ITER-India cryogenics laboratory in order to verify the thermal performance and mechanical integrity. The primary objectives, which are evaluated during the PTCL test, are (i) Thermal performance of the PTCL (ii) Measurement of temperature profile on thermal shield of PTCL, (iii) Stress measurement at critical locations, (iv) Measurement of Outer Vacuum Jacket (OVJ) temperature during Break of Insulation Vacuum (BIV) test. The paper will summarize the methodology and observed results of PTCL.

【 预 览 】
附件列表
Files Size Format View
Acceptance tests and their results for 1st Pre-Series Cryoline (PTCL) of ITER 3209KB PDF download
  文献评价指标  
  下载次数:19次 浏览次数:26次