会议论文详细信息
26th International Cryogenic Engineering Conference & International Cryogenic Materials Conference 2016
Design of a 0-50 mbar pressure measurement channel compatible with the LHC tunnel radiation environment
材料科学;物理学
Casas, Juan^1 ; Jelen, Dorota^1 ; Trikoupis, Nikolaos^1
CERN, Dept. TE-CRG, Geneva 23
1211, Switzerland^1
关键词: Bayonet heat exchanger;    Contactless technique;    Differential pressure sensor;    Operational experience;    Passive pressure sensors;    Radiation environments;    Saturation temperature;    Variable reluctance sensors;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/171/1/012141/pdf
DOI  :  10.1088/1757-899X/171/1/012141
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

The monitoring of cryogenic facilities often require the measurement of pressure in the sub 5'000 Pa range that are used for flow metering applications, for saturated superfluid helium, etc. The pressure measurement is based on the minute displacement of a sensing diaphragm often through contactless techniques by using capacitive or inductive methods. The LHC radiation environment forbid the use of standard commercial sensors because of the embedded electronics that are affected both by radiation induced drift and transient Single Event Effects (SEE). Passive pressure sensors from two manufacturers were investigated and a CERN designed radiation-tolerant electronics has been developed for measuring variable-reluctance sensors. During the last maintenance stop of the LHC accelerator, four absolute pressure sensors were installed in some of the low pressure bayonet heat exchangers and four differential pressure sensors on the venturi flowmeters that monitor the cooling flow of the 20.5 kA current leads of the ATLAS end-cap superconducting toroids. The pressure sensors operating range is about 1000 to 5000 Pa and the targeted uncertainty is +/- 50 Pa which would permit to measure the equivalent saturation temperature at 1.8 K within better than 0.01 K. This paper describes the radiation hard measuring head that is based on an inductive bridge, its associated radiation-tolerant electronics that is installed under the LHC superconducting magnets or the ATLAS detector cavern; and the first operational experience.

【 预 览 】
附件列表
Files Size Format View
Design of a 0-50 mbar pressure measurement channel compatible with the LHC tunnel radiation environment 1374KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:44次