| International Conference on Advances in Materials and Manufacturing Applications 2016 | |
| Evaluation of slurry erosion wear characteristic of plasma sprayed TiO2 coated 410 steel | |
| Rao, K.V. Sreenivas^1 ; Girisha, K.G.^1 ; Rakesh, Y.D.^1 | |
| Department of Mechanical Engineering, Siddaganga Institute of Technology, Karnataka, Tumkur | |
| 572103, India^1 | |
| 关键词: Erosion mechanisms; Hardness values; Microhardness tests; Oxide particles; Plasma sprayed; Rotational speed; Sand concentrations; Slurry erosion; | |
| Others : https://iopscience.iop.org/article/10.1088/1757-899X/149/1/012067/pdf DOI : 10.1088/1757-899X/149/1/012067 |
|
| 来源: IOP | |
PDF
|
|
【 摘 要 】
In the present study, slurry erosion performance of plasma sprayed Titanium oxide (TiO2) coatings on AISI 410 steel has been investigated. Erosion studies were performed on uncoated and plasma sprayed TiO2coated steel using slurry erosion test rig at room temperature by varying the rotational speed (500, 750, 1000, and 1500), keeping sand concentration and time as constant. To know the erosion mechanism, SEM microphotographs were taken before and after the erosion test. EDX analysis confirms the presence of Titanium oxide particles. Vickers's micro hardness test was performed on the surface of both coated and un-coated samples to access the hardness value. Plasma sprayed titanium oxide coated 410 grade steel showed superior slurry erosion resistance as compared to un coated steel. It may be due to higher hardness and less porosity of Tio2coated steel substrates.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| Evaluation of slurry erosion wear characteristic of plasma sprayed TiO2 coated 410 steel | 1760KB |
PDF