| 7th International Conference on Pumps and Fans | |
| Performance test of electromagnetic pump on heavy liquid metal in PREKY-I facility | |
| 机械制造;工业技术 | |
| Li, X.L.^1 ; Ma, X.D.^1 ; Zhu, Z.Q.^1 ; Li, Y.^1 ; Lv, K.F.^1,2 | |
| Key Laboratory of Neutronics and Radiation Safety, Chinese Academy of Sciences, Institute of Nuclear Energy Safety Technology, Hefei, Anhui | |
| 230031, China^1 | |
| University of Science and Technology of China, Hefei, Anhui | |
| 230027, China^2 | |
| 关键词: Design parameters; Experimental loop; Heavy liquid metal; Mechanical performance; Outlet temperature; Performance tests; Stable performance; Working current; | |
| Others : https://iopscience.iop.org/article/10.1088/1757-899X/129/1/012024/pdf DOI : 10.1088/1757-899X/129/1/012024 |
|
| 学科分类:工业工程学 | |
| 来源: IOP | |
PDF
|
|
【 摘 要 】
Pump is a key sub-system which drives the heavy liquid metal circulation in experimental loops. In the paper, the hydraulic and mechanical performances of an electromagnetic pump (EMP) were tested in the liquid metal test facility named PREKY-I. The test results showed that the EMP worked at good state when the working current was up to 170 ampere. In this condition, the flow rate was 5m3/h, and pressure head 7.5bar, when the outlet temperature was kept at 380°C during the test. The performance was close to the expected design parameters. The EMP had run continuously for 200 hours with stable performance. From the test results, the EMP could be used in KYLIN-II loop, which is the upgrade liquid metal test loop of PREKY-I.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| Performance test of electromagnetic pump on heavy liquid metal in PREKY-I facility | 876KB |
PDF