会议论文详细信息
7th International Conference on Pumps and Fans
Performance test of electromagnetic pump on heavy liquid metal in PREKY-I facility
机械制造;工业技术
Li, X.L.^1 ; Ma, X.D.^1 ; Zhu, Z.Q.^1 ; Li, Y.^1 ; Lv, K.F.^1,2
Key Laboratory of Neutronics and Radiation Safety, Chinese Academy of Sciences, Institute of Nuclear Energy Safety Technology, Hefei, Anhui
230031, China^1
University of Science and Technology of China, Hefei, Anhui
230027, China^2
关键词: Design parameters;    Experimental loop;    Heavy liquid metal;    Mechanical performance;    Outlet temperature;    Performance tests;    Stable performance;    Working current;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/129/1/012024/pdf
DOI  :  10.1088/1757-899X/129/1/012024
学科分类:工业工程学
来源: IOP
PDF
【 摘 要 】

Pump is a key sub-system which drives the heavy liquid metal circulation in experimental loops. In the paper, the hydraulic and mechanical performances of an electromagnetic pump (EMP) were tested in the liquid metal test facility named PREKY-I. The test results showed that the EMP worked at good state when the working current was up to 170 ampere. In this condition, the flow rate was 5m3/h, and pressure head 7.5bar, when the outlet temperature was kept at 380°C during the test. The performance was close to the expected design parameters. The EMP had run continuously for 200 hours with stable performance. From the test results, the EMP could be used in KYLIN-II loop, which is the upgrade liquid metal test loop of PREKY-I.

【 预 览 】
附件列表
Files Size Format View
Performance test of electromagnetic pump on heavy liquid metal in PREKY-I facility 876KB PDF download
  文献评价指标  
  下载次数:25次 浏览次数:23次