会议论文详细信息
18th Chemnitz Seminar on Materials Engineering – 18. Werkstofftechnisches Kolloquium
Simulations and measurements of annealed pyrolytic graphite-metal composite baseplates
Streb, F.^1 ; Ruhl, G.^1 ; Schubert, A.^2 ; Zeidler, H.^2 ; Penzel, M.^2 ; Flemmig, S.^2 ; Todaro, I.^3 ; Squatrito, R.^3 ; Lampke, T.^4
Infineon Technologies AG, Germany^1
Prof. Micromanufacturing Technology, Technische Universitaet Chemnitz, Germany^2
CIRI - Advanced Applications in Mechanical Engineering and Materials Technology, University of Bologna, Italy^3
Materials and Surface Engineering Group, Institute of Materials Science and Engineering, Technische Universität Chemnitz, Chemnitz
09125, Germany^4
关键词: Aluminum matrix composites;    Annealed pyrolytic graphite;    Finite element simulations;    Nonisothermal simulation;    Power semiconductor module;    Simulations and measurements;    Thermal boundary conditions;    Thermal contact conductance;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/118/1/012013/pdf
DOI  :  10.1088/1757-899X/118/1/012013
来源: IOP
PDF
【 摘 要 】

We investigated the usability of anisotropic materials as inserts in aluminum-matrix-composite baseplates for typical high performance power semiconductor modules using finite-element simulations and transient plane source measurements. For simulations, several physical modules can be used, which are suitable for different thermal boundary conditions. By comparing different modules and options of heat transfer we found non-isothermal simulations to be closest to reality for temperature distribution at the surface of the heat sink. We optimized the geometry of the graphite inserts for best heat dissipation and based on these results evaluated the thermal resistance of a typical power module using calculation time optimized steady-state simulations. Here we investigated the influence of thermal contact conductance (TCC) between metal matrix and inserts on the heat dissipation. We found improved heat dissipation compared to the plain metal baseplate for a TCC of 200 kW/m2/K and above.To verify the simulations we evaluated cast composite baseplates with two different insert geometries and measured their averaged lateral thermal conductivity using a transient plane source (HotDisk) technique at room temperature. For the composite baseplate we achieved local improvements in heat dissipation compared to the plain metal baseplate.

【 预 览 】
附件列表
Files Size Format View
Simulations and measurements of annealed pyrolytic graphite-metal composite baseplates 1386KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:25次