会议论文详细信息
4th Global Conference on Materials Science and Engineering
Enhanced mercury removal from fix-bed reactor by lamella manganese oxide sorbents
Cheng, H.W.^1 ; Yu, C.T.^1
Chemistry Division, Institute of Nuclear Energy Research, Longtan
325, Taiwan^1
关键词: Coprecipitation method;    Fix-bed reactors;    Hazardous metals;    Mercuries (Hg);    Mercury removal;    Removal efficiencies;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/103/1/012042/pdf
DOI  :  10.1088/1757-899X/103/1/012042
来源: IOP
PDF
【 摘 要 】
Mercury (Hg) is an extremely hazardous metal and attracted more concern because of its high toxicity and bioaccumulation. Several manganese-oxide-containing sorbents prepared by co-precipitation method could exhibit the mercury removal activities toward Hg0. The mercury removal test at the temperature of 300°C has the highest removal efficiency. Under this temperature, the maximum absorption equivalent of Mg-Al-Mn and Mn-Al were up to 90.9 and 247 μg/g, then gradually decreased at 400°C. The mercury removal efficiency declined in the following sequence: Mn-Al > Mg-Al-Mn > Mg-Al-Mn/AC/Mn/AC(p)> Mn/AC(g), due to the manganese-oxide content formed on the sorbents.
【 预 览 】
附件列表
Files Size Format View
Enhanced mercury removal from fix-bed reactor by lamella manganese oxide sorbents 943KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:40次