会议论文详细信息
Cryogenic Engineering Conference 2015
Performance evaluation of a developed orifice type heater for thermal compensation control at J-PARC cryogenic hydrogen system
材料科学;物理学
Tatsumoto, H.^1 ; Aso, T.^1 ; Ohtsu, K.^1 ; Kawakami, Y.^1
J-PARC Center, JAEA, Tokai-Ibaraki
319-1195, Japan^1
关键词: Dynamic simulation codes;    Hydrogen pressures;    Hydrogen system;    Nuclear heating;    Performance evaluations;    Performance tests;    Simulation model;    Thermal compensation;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/101/1/012108/pdf
DOI  :  10.1088/1757-899X/101/1/012108
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

Supercritical hydrogen with a temperature of less than 20 K and a pressure of 1.5 MPa is used as moderator material at J-PARC. Total nuclear heating of 3.75 kW is generated by three moderators for a 1-MW proton beam operation. We have developed an orifice-type high-power heater for thermal compensation to mitigate hydrogen pressure fluctuation caused by the abrupt huge heat load and to reduce the fluctuation in the temperature of the supply hydrogen to less than 0.25 K. Through a performance test, we confirmed that the developed orifice-type heater could be heated uniformly and showed fast response, as expected. Furthermore, a simulation model that can describe heater behaviors has been established on the basis of the experimental data. The heater control approach was studied using the aforementioned heater simulation model and a dynamic simulation code developed by the authors.

【 预 览 】
附件列表
Files Size Format View
Performance evaluation of a developed orifice type heater for thermal compensation control at J-PARC cryogenic hydrogen system 949KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:29次