会议论文详细信息
Cryogenic Engineering Conference 2015
Study for cryogenic testing the Super-FRS magnets of FAIR in a new test facility at CERN
材料科学;物理学
Derking, J.H.^1 ; Perin, A.^1 ; Benda, V.^1 ; Pirotte, O.^1
CERN, Technology Department, Cryogenics Group, Geneva
23, 1211, Switzerland^1
关键词: Cryogenic test facility;    Cryogenic testing;    Facility for antiproton and ion research;    Liquid helium;    Magnet tests;    Maximum cooling;    Nominal operations;    Operational parameters;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/101/1/012104/pdf
DOI  :  10.1088/1757-899X/101/1/012104
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

The Super-FRS magnets of the international Facility for Antiproton and Ion Research (FAIR) being built at GSI in Germany will be tested at a new cryogenic test facility currently under construction at CERN. During nominal operation the magnets will be cooled with liquid helium to 4.5 K. Over a period of three years in total 57 magnets will be tested of three different types. A study is performed to determine the cryogenic requirements for testing the Super-FRS magnets. The required operational parameters for the cool down, magnet test and warm up phases are determined and the results are discussed in this paper. For pre-cooling the magnets to 90 K with a rate of 1 Kh-1, a maximum cooling power of 5.6 kW is required. Cooling down the magnets further to 4.5 K and filling will be performed with LHe within 24 h. For warming up the magnets a maximum heater power of 14 kW is needed. It is concluded that the planned test facility currently under construction at CERN fulfills the cryogenic requirements for testing the Super-FRS magnets.

【 预 览 】
附件列表
Files Size Format View
Study for cryogenic testing the Super-FRS magnets of FAIR in a new test facility at CERN 660KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:14次