会议论文详细信息
Cryogenic Engineering Conference 2015
Experimental and CFD analyses of a thermal radiation shield dimple plate for cryogenic pump application
材料科学;物理学
Scannapiego, M.^1 ; Day, C.^1
Karlsruhe Institute of Technology, Institute for Technical Physics, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopolshafen
76344, Germany^1
关键词: Cryogenic pumps;    Cryogenic temperatures;    Design solutions;    Heat transfer characteristics;    High heat flux;    Operation conditions;    Pumping operations;    Regeneration cycles;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/101/1/012068/pdf
DOI  :  10.1088/1757-899X/101/1/012068
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

Large customized cryogenic pumps are used in fusion reactors to evacuate the plasma exhaust from the torus. Cryopumps usually consist of an active pumping surface area cooled below 5 K and shielded from direct outer thermal radiation by plates cooled at 80K. In nuclear fusion applications, cryopumps are exposed to excessively high heat fluxes during pumping operation, and follow-up regeneration cycles with rapid warm-up and cool-down phases. Therefore, high cryogenic operational mass flows are required and thus pressure drop and heat transfer characteristics become key issues for the design of the pump cryogenic circuits. Actively cooled dimple plates are a preferred design solution for the thermal radiation shield. A test plate with a rhomb pattern of dimples has been manufactured and tested in terms of pressure drop with a dedicated test facility using water. In the present work, computational fluid dynamics (CFD) models of the test dimple plate have been performed, and computed pressure drops have been compared to experimental results. Despite the complexity of the geometry, a good agreement with the experimental results was found. Then, the validated CFD approach has been further extended to relevant operation conditions, using gaseous helium at cryogenic temperature as working fluid. The resulting pressure drop and heat transfer characteristics are finally presented.

【 预 览 】
附件列表
Files Size Format View
Experimental and CFD analyses of a thermal radiation shield dimple plate for cryogenic pump application 1590KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:73次