会议论文详细信息
Cryogenic Engineering Conference 2015
Experimental study of stability and transients in a horizontally heated boiling helium thermosyphon
材料科学;物理学
Furci, H.^1 ; Four, A.^1 ; Baudouy, B.^1
CEA Saclay, Irfu/SACM, Gif-sur-Yvette
91191, France^1
关键词: Heated sections;    Magnet protection;    Natural circulation loop;    Power stability;    Steady and transient;    Temperature oscillations;    Vertical risers;    Wall temperatures;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/101/1/012062/pdf
DOI  :  10.1088/1757-899X/101/1/012062
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

Experiments were conducted on a liquid helium natural circulation loop with a 4 m long horizontal heated section. Wall temperatures on the heated section, mass ow rate and pressure drop were measured in steady and transient regimes. The stability of the loop has been studied and the power stability limits have been found. Also, different heating configurations were explored and their drawbacks and benefits were observed. The result is that the loop is stable only above a non-zero low power and below a certain upper power limit. The distance from the heating to the vertical riser affects the stability range. It has been found that instabilities at low power or transients following a low power step pulse can produce considerable temperature oscillations, potentially dangerous from the magnet protection point of view.

【 预 览 】
附件列表
Files Size Format View
Experimental study of stability and transients in a horizontally heated boiling helium thermosyphon 2319KB PDF download
  文献评价指标  
  下载次数:38次 浏览次数:10次