9th International Conference on Compressors and their Systems | |
Gas dynamic design of the pipe line compressor with 90% efficiency. Model test approval | |
Galerkin, Y.^1 ; Rekstin, A.^1 ; Soldatova, K.^1 | |
R and D Laboratory Gas Dynamics of Turbo Machines, Peter the Great St. Petersburg Polytechnic University, Polytechnical st. 29, St.Petersburg, Russia^1 | |
关键词: Compressor efficiency; Design points; Dynamic design; Efficiency loss; Maximum Efficiency; Standard optimization; Technical specifications; Universal model; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/90/1/012044/pdf DOI : 10.1088/1757-899X/90/1/012044 |
|
来源: IOP | |
![]() |
【 摘 要 】
Gas dynamic design of the pipe line compressor 32 MW was made for PAO SMPO (Sumy, Ukraine). The technical specification requires compressor efficiency of 90%. The customer offered favorable scheme - single-stage design with console impeller and axial inlet. The authors used the standard optimization methodology of 2D impellers. The original methodology of internal scroll profiling was used to minimize efficiency losses. Radically improved 5th version of the Universal modeling method computer programs was used for precise calculation of expected performances. The customer fulfilled model tests in a 1:2 scale. Tests confirmed the calculated parameters at the design point (maximum efficiency of 90%) and in the whole range of flow rates. As far as the authors know none of compressors have achieved such efficiency. The principles and methods of gas-dynamic design are presented below. The data of the 32 MW compressor presented by the customer in their report at the 16thInternational Compressor conference (September 2014, Saint- Petersburg) and later transferred to the authors.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Gas dynamic design of the pipe line compressor with 90% efficiency. Model test approval | 1457KB | ![]() |