会议论文详细信息
1st Physics and Technologies in Medicine and Dentistry Symposium
Tolerance of brightness and contrast adjustments on chronic apical abscess and apical granuloma interpretation
物理学;医药卫生
Purnamasari, L.^1 ; Iskandar, H.H.B.^1 ; Makes, B.N.^1
Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Universitas Indonesia, Jakarta, Indonesia^1
关键词: Contrast adjustment;    Digitized radiography;    Subjective image quality;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/884/1/012141/pdf
DOI  :  10.1088/1742-6596/884/1/012141
学科分类:卫生学
来源: IOP
PDF
【 摘 要 】
In digitized radiography techniques, adjusting the image enhancement can improve the subjective image quality by optimizing the brightness and contrast for diagnostic needs. To determine the value range of image enhancement (brightness and contrast) on chronic apical abscess and apical granuloma interpretation. 30 periapical radiographs that diagnosed chronic apical abscess and 30 that diagnosed apical granuloma were adjusted by changing brightness and contrast values. The value range of brightness and contrast adjustment that can be tolerated in radiographic interpretations of chronic apical abscess and apical granuloma spans from -10 to +10. Brightness and contrast adjustments on digital radiographs do not affect the radiographic interpretation of chronic apical abscess and apical granuloma if conducted within the value range.
【 预 览 】
附件列表
Files Size Format View
Tolerance of brightness and contrast adjustments on chronic apical abscess and apical granuloma interpretation 328KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:31次