会议论文详细信息
30th International Conference on Photonic, Electronic, and Atomic Collisions
Effective solid angle correction factors for long-lived Auger states populated in low-Z ion collisions with gas targets
Benis, E.P.^1 ; Nanos, S.^1 ; Madesis, I.^2,3 ; Laoutaris, A.^2,3 ; Gorczyca, T.W.^4 ; Zouros, T.J.M.^2,3
Department of Physics, University of Ioannina, Ioannina
GR 45110, Greece^1
Department of Physics, University of Crete, P.O. Box 2208, Heraklion
GR 71003, Greece^2
Tandem Accelerator Laboratory, INPP, NCSR Demokritos, Ag. Paraskevi
GR 15310, Greece^3
Department of Physics, Western Michigan University, Kalamazoo
MI
49008, United States^4
关键词: Auger spectrum;    Auger state;    Correction factors;    Effective solid angle;    High resolution;    Ion collisions;    Parallel plates;    Simulations and measurements;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/875/10/092007/pdf
DOI  :  10.1088/1742-6596/875/10/092007
来源: IOP
PDF
【 摘 要 】

Synopsis: Effective solid angle correction factors for two high resolution electrostatic spectrometers - a hemispherical and a tandem parallel plate - are determined using SIMION Monte Carlo simulations. Results are compared to experimental correction factors directly determined from Auger spectra produced by 1s ionization in collisions of 6.6 MeV C2+(1s22s21S, 1s22s2p3P) mixed state ion beams with H2 targets. Excellent agreement between simulation and measurement is found.

【 预 览 】
附件列表
Files Size Format View
Effective solid angle correction factors for long-lived Auger states populated in low-Z ion collisions with gas targets 70KB PDF download
  文献评价指标  
  下载次数:17次 浏览次数:16次