Field quality of 1.5 m long conduction cooled superconducting undulator coils with 20 mm period length
Casalbuoni, S.^1 ; Glamann, N.^1 ; Grau, A.W.^1 ; Holubek, T.^1 ; Saez De Jauregui, D.^1 ; Boffo, C.^2 ; Gerhard, Th.A.^2 ; Turenne, M.^2 ; Walter, W.^2
Institute for Beam Physics and Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen
D-76344, Germany^1
Babcock Noell GmbH, Würzburg
97080, Germany^2
关键词: Conduction cooled;    Field integral;    Industrial partners;    Local magnetic field;    Low emittance;    Photon spectra;    Superconducting undulators;    Synchrotron light source;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/874/1/012015/pdf
DOI  :  10.1088/1742-6596/874/1/012015
来源: IOP
PDF
【 摘 要 】

The Institute for Beam Physics and Technology (IBPT) at the Karlsruhe Institute of Technology (KIT) and the industrial partner Babcock Noell GmbH (BNG) are collaborating since 2007 on the development of superconducting undulators both for ANKA and low emittance light sources. The first full length device with 15 mm period length has been successfully tested in the ANKA storage ring for one year. The next superconducting undulator has 20 mm period length (SCU20) and is also planned to be installed in the accelerator test facility and synchrotron light source ANKA. The SCU20 1.5 m long coils have been characterized in a conduction cooled horizontal test facility developed at KIT IBPT. Here we present the local magnetic field and field integral measurements, as well as their analysis including the expected photon spectrum.

【 预 览 】
附件列表
Files Size Format View
Field quality of 1.5 m long conduction cooled superconducting undulator coils with 20 mm period length 849KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:13次