会议论文详细信息
International Conference on Physical Instrumentation and Advanced Materials
Optimization image of magnetic resonance imaging (MRI) T2 fast spin echo (FSE) with variation echo train length (ETL) on the rupture tendon achilles case
物理学;材料科学
Muzamil, Akhmad^1,3 ; Firmansyah, Achmad Haries^2
Department of Biomedical Engineering, Post Graduate School, Airlangga University, Indonesia^1
Department of Physics, Faculty of Science and Technology, Airlangga University, Indonesia^2
Haji Hospital of Surabaya, Indonesia^3
关键词: Contrast to noise ratio;    Fast spin echos;    Magnetic Resonance Imaging (MRI);    Mri imaging;    Noise ratio;    Optimal images;    Tendon tissues;    The region of interest (ROI);   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/853/1/012020/pdf
DOI  :  10.1088/1742-6596/853/1/012020
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

The research was done the optimization image of Magnetic Resonance Imaging (MRI) T2 Fast Spin Echo (FSE) with variation Echo Train Length (ETL) on the Rupture Tendon Achilles case. This study aims to find the variations Echo Train Length (ETL) from the results of ankle's MRI image and find out how the value of Echo Train Length (ETL) works on the MRI ankle to produce optimal image. In this research, the used ETL variations were 12 and 20 with the interval 2 on weighting T2 FSE sagittal. The study obtained the influence of Echo Train Length (ETL) on the quality of ankle MRI image sagittal using T2 FSE weighting and analyzed in 25 images of five patients. The data analysis has done quantitatively with the Region of Interest (ROI) directly on computer MRI image planes which conducted statistical tests Signal to Noise Ratio (SNR) and Contras to Noise Ratio (CNR). The Signal to Noise Ratio (SNR) was the highest finding on fat tissue, while the Contras to Noise Ratio (CNR) on the Tendon-Fat tissue with ETL 12 found in two patients. The statistics test showed the significant SNR value of the 0.007 (p0.05) of the Fat, 0.912 (p>0.05) of the Fibula, and 0.436 (p>0.05) of the Heel Bone. For the contrast to noise ratio (CNR) of the Tendon-FAT tissue was about 0.041 (p>0.05). The results of the study showed that ETL variation with T2 FSE sagittal weighting had difference at Tendon tissue and Tendon-Fat tissue for MRI imaging quality. SNR and CNR were an important aspect on imaging optimization process to give the diagnose information.