Fault Diagnosis for Centre Wear Fault of Roll Grinder Based on a Resonance Demodulation Scheme
Wang, Liming^1 ; Shao, Yimin^1 ; Yin, Lei^1 ; Yuan, Yilin^2 ; Liu, Jing^1
State Key Laboratory of Mechanical Transmission, Chongqing University, China^1
Ningbo Baoxin Stainless Steel Co., Ltd., Ningbo, Zhejiang, China^2
关键词: Alternating stress;    Envelope spectra;    Filtered signals;    Grinding process;    Health indicators;    Resonance demodulation;    Roll surfaces;    Steel strip;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/842/1/012057/pdf
DOI  :  10.1088/1742-6596/842/1/012057
来源: IOP
PDF
【 摘 要 】

Roll grinder is one of the important parts in the rolling machinery, and the grinding precision of roll surface has direct influence on the surface quality of steel strip. However, during the grinding process, the centre bears the gravity of the roll and alternating stress. Therefore, wear or spalling faults are easily observed on the centre, which will lead to an anomalous vibration of the roll grinder. In this study, a resonance demodulation scheme is proposed to detect the centre wear fault of roll grinder. Firstly, fast kurtogram method is employed to help select the sub-band filter parameters for optimal resonance demodulation. Further, the envelope spectrum are derived based on the filtered signal. Finally, two health indicators are designed to conduct the fault diagnosis for centre wear fault. The proposed scheme is assessed by analysing experimental data from a roll grinder of twenty-high rolling mill. The results show that the proposed scheme can effectively detect the centre wear fault of the roll grinder.

【 预 览 】
附件列表
Files Size Format View
Fault Diagnosis for Centre Wear Fault of Roll Grinder Based on a Resonance Demodulation Scheme 512KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:42次