Design and testing of fluid resistor for repetitive high-voltage pulse generator
Poloskov, A.V.^1 ; Egorov, I.S.^1 ; Serebrennikov, M.A.^1
National Research Tomsk Polytechnic University, Lenin Ave. 30, Tomsk
634050, Russia^1
关键词: Depressurizations;    Electrical strength;    Electrolyte heating;    Generator load;    High voltage generators;    High-voltage pulse generator;    Load resistances;    Resistive loads;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/830/1/012047/pdf
DOI  :  10.1088/1742-6596/830/1/012047
来源: IOP
PDF
【 摘 要 】

The paper presents a design and the results of testing of the liquid resistive load for a repetitive high-voltage generator (200 kV, 0.5 ms). The load uses a sealed dielectric case, which is to be placed into a vacuum volume (5×10-4Torr) for electrical strength ensuring. Repetitive testing of the generator with the load (10 pps) caused the electrolyte heating, the load resistance decreasing, and the changing of a generator mode. An expansion tank is used to compensate thermal expansion of the electrolyte, which makes it possible to absorb up to 1 MJ of energy in the load without seals breaking. A generator load curve can be obtained for one experiment with a help of the fluid load without any additional depressurization of the vacuum volume.