10th Asia Plasma and Fusion Association Conference | |
Thermo-mechanical Design Methodology for ITER Cryodistribution cold boxes | |
Shukla, Vinit^1 ; Patel, Pratik^1 ; Das, Jotirmoy^1 ; Vaghela, Hitensinh^1 ; Bhattacharya, Ritendra^1 ; Shah, Nitin^1 ; Choukekar, Ketan^1 ; Chang, Hyun-Sik^2 ; Sarkar, Biswanath^1 | |
ITER-India, Institute for Plasma Research, A-29 GIDC Electronics Estate, Gandhinagar, Gujarat | |
382016, India^1 | |
ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, St.Paul Lez Durance Cedex | |
13067, France^2 | |
关键词: Cold compressors; Cryogenic valves; Load combination; Magnet structure; Nominal operations; Pressure and temperature; Steady-state condition; Thermo-mechanical design; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/823/1/012043/pdf DOI : 10.1088/1742-6596/823/1/012043 |
|
来源: IOP | |
【 摘 要 】
The ITER cryo-distribution (CD) system is in charge of proper distribution of the cryogen at required mass flow rate, pressure and temperature level to the users; namely the superconducting (SC) magnets and cryopumps (CPs). The CD system is also capable to use the magnet structures as a thermal buffer in order to operate the cryo-plant as much as possible at a steady state condition. A typical CD cold box is equipped with mainly liquid helium (LHe) bath, heat exchangers (HX's), cryogenic valves, filter, heaters, cold circulator, cold compressor and process piping. The various load combinations which are likely to occur during the life cycle of the CD cold boxes are imposed on the representative model and impacts on the system are analyzed. This study shows that break of insulation vacuum during nominal operation (NO) along with seismic event (Seismic Level-2) is the most stringent load combination having maximum stress of 224 MPa. However, NO+SMHV (Séismes Maximaux Historiquement Vraisemblables = Maximum Historically Probable Earthquakes) load combination is having the least safety margin and will lead the basis of the design of the CD system and its sub components. This paper presents and compares the results of different load combinations which are likely to occur on a typical CD cold box.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Thermo-mechanical Design Methodology for ITER Cryodistribution cold boxes | 1092KB | download |