会议论文详细信息
34th UIT Heat Transfer Conference 2016
Optimization of a single-stage double-suction centrifugal pump
Škerlavaj, A.^1,2 ; Morgut, M.^1,2 ; Jot, D.^1 ; Nobile, E.^2
Kolektor Turboinstitut D.d., Rovsnikova 7, Ljubljana
1210, Slovenia^1
Dipartimento di Ingegneria e Architettura, Università degli Studi di Trieste, via A. Valerio 10, Trieste
34127, Italy^2
关键词: 3d cfd modeling;    Double suction pumps;    Double-suction centrifugal pumps;    Evolutionary design;    Hydraulic efficiency;    Radial basis functions;    Response surface;    Stepwise regression;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/796/1/012007/pdf
DOI  :  10.1088/1742-6596/796/1/012007
来源: IOP
PDF
【 摘 要 】

In this study, the objective of the optimization of a double-suction pump is the maximization of its hydraulic efficiency. The optimization is performed, by means of the modeFRONTIER optimization platform, in steps. At first, by means of a DOE (Design of Experiments) strategy, the design space is explored, using a parameterized CAD representation of the pump. Suitable metamodels (surrogates or Response Surfaces), which represent an economical alternative to the more expensive 3D CFD model, are built and tested. Among different metamodels, the evolutionary design, radial basis function and the stepwise regression models seem to be the most promising ones. Finally, the stepwise regression model, trained on a set of 200 designs and constructed with only five the most influential input design parameters, was chosen as a potentially applicable metamodel.

【 预 览 】
附件列表
Files Size Format View
Optimization of a single-stage double-suction centrifugal pump 3493KB PDF download