| Hotspot Liquid Microfluidic Cooling: Comparing The Efficiency between Horizontal Flow and Vertical Flow | |
| 物理学;能源学 | |
| Okamoto, Yuki^1 ; Ryoson, Hiroyuki^2 ; Fujimoto, Koji^2 ; Honjo, Keiji^2 ; Ohba, Takayuki^2 ; Mita, Yoshio^1 | |
| Dept. EEIS, Univ. of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo | |
| 113-8656, Japan^1 | |
| Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Kanagawa, Yokohama | |
| 226-8501, Japan^2 | |
| 关键词: Circuit blocks; Cooling methods; Cooling scheme; Efficiency limits; High temperature; Horizontal flows; Microfluidic cooling; Phase Locked Loop (PLL); | |
| Others : https://iopscience.iop.org/article/10.1088/1742-6596/773/1/012066/pdf DOI : 10.1088/1742-6596/773/1/012066 |
|
| 来源: IOP | |
PDF
|
|
【 摘 要 】
This paper reports a novel cooling method for a local high-temperature block in an integrated circuit, which is called a "hotspot". The method is to cool the chip in out-of-plane (3-D) direction to overcome efficiency limit of traditional horizontal (2-D) cooling. Our result indicates that high-temperature (over 180 C) circuit block such as a phase-locked-loop (PLL), which is a performance limiting block in a modern CPU, can more efficiently be cooled by the vertical (3-D) cooling scheme.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| Hotspot Liquid Microfluidic Cooling: Comparing The Efficiency between Horizontal Flow and Vertical Flow | 817KB |
PDF